02/14/2006 NI806 Electric Furnace Installation & Operating Instructions HE-E-**-21 Series Application Special non-WarmFlo, non-heat pump, st
02/14/2006 8 NI806 Whether this unit is sitting on or attached to an inlet cabinet, field designed inlet cabinet, or horizontal supports; verify prop
02/14/2006 9 NI806 Horizontal, Air Conditioning Similar to upflow above, the air conditioning coil is positioned at the blower outlet. Depending up
02/14/2006 10 NI806 Electrical Installation WARNING TO AVOID THE RISK OF ELECTRIC SHOCK OR DEATH, WIRING TO THE UNIT MUST BE PROPERLY GROUNDED. FA
02/14/2006 11 NI806 Cooling, Special Dehumidification The BK tab and the BK peg jumper provide the industry standard 12% blower speed reduction to “p
02/14/2006 12 NI806 Electric Furnace Control – Inside View, Right Board Green, next to Fuse 24-volt power connected and fuse good. Red, next to W C
02/14/2006 13 NI806 Replacement Parts @HEIBG6707 PCB Electric Furnace ECM™ Motor H/C and HP Stat @EMD3I6600 PCB EM DI 3-Stage 5850 Motor ½ HP ECM
ELECTRO INDUSTRIES, INC.MONTICELLO, MN 55362NON-WARMFLO, HEAT/COOL STAT, A/C (1 SPEED)HE-E-**-21NH80811-03-05J3TB2TB1T5T6F1T8T7T1T2T4T3T15LED4LED1J7T1
ELECTRO INDUSTRIES, INC.MONTICELLO, MN 55362NON-WARMFLO, HEAT/COOL STAT, A/C (2 SPEED)HE-E-**-21NH80911-03-05J3TB2TB1T5T6F1T8T7T1T2T4T3T15LED4LED1J7T1
NS803 P1Rev.B 03-09-07ELECTRO INDUSTRIES, INC.MONTICELLO, MN 55362Air Handler (HE-E-20-21), Basic Staging ECMWIRING SCHEMATICAIR HANDLER BASIC STAGING
NS803 P2Rev.B 03-09-07ELECTRO INDUSTRIES, INC.MONTICELLO, MN 55362Air Handler (HE-E-15-21), Basic Staging ECMWIRING SCHEMATICDIPC2K7K6K5L1L1L1RWRWRRRR
02/14/2006 NI806 Table of Contents Configurator 1 Inlet Cabinets 2 General Comments 3 Application 4 Installation Requirements 6 Mechanical Insta
NS803 P3Rev.B 03-09-07ELECTRO INDUSTRIES, INC.MONTICELLO, MN 55362Air Handler (HE-E-10-21), Basic Staging ECMWIRING SCHEMATICAIR HANDLER BASIC STAGING
Page 1 of 2 XX017 Electro Industries, Inc. Limited Product Warranty Effective February 5, 2009 Electro Industries, Inc. warrants to the original
Page 2 of 2 XX017 THESE WARRANTIES DO NOT COVER: 1. Costs for labor for removal and reinstallation of an alleged defective product or product par
02/14/2006 1 NI806 Configurator HE-T-KW-CW Type Cabinet Width H, A, E, N 21 = 21” (see below) 24 = 24”* kW S
02/14/2006 2 NI806 Inlet Cabinets Factory optional cabinets can be configured with this Electric Furnace. Typically these are designed for upflow a
02/14/2006 3 NI806 General Comments Upflow/Downflow/Horizontal The arrangement of refrigerant coil, hydronics coil, and built-in electric elements n
02/14/2006 4 NI806 Installation Checkout Attached to this manual is a warranty certification and checkout procedure. This must be completed and retu
02/14/2006 5 NI806 Specification Chart Model Number HE-E-10-21 HE-E-15-21 HE-E-20-21 Cabinet Width 21” 21” 21” kW rating 10 15 20 Btu/h 340
02/14/2006 6 NI806 Installation Requirements 1. All installation work must be performed by trained, qualified contractors or technicians. Electro
02/14/2006 7 NI806 Mechanical Installation Clearances and Accessibility Zero clearance is allowed on all sides for combustible materials. However,
Comments to this Manuals